Job abend Codes

Lista de Abend Codes mais frequentes:

CC=0001 - (1016) PIE JOBS - BAD PART NUMBER - FOLLOW PACBOOK VERY CAREFULLY
CC=001 - I/O ERROR
CC=002 - I/O INVALID RECORD
CC=0004 - DATASET NOT FOUND, TABLESPACE IN COPY PENDING, ETC… MAY BE OK(CHECK COND STATEMENTS OR CALL ADM TO VERIFY)
CC=0008 - EQUIP CHECK, UNABLE TO DBR DB RLAO00, RC-08, SQL ERROR, EMPTY DATASET
CC=0010 - (CC=0016 IN HEX) BAD DATA
CC=0012 - I/O ERROR TAPE, VSAM DATASETS CLOSED, INVALID DATA, EMPTY TABLE, COULD BE ANYTHING
CC=0014 -
CC=0016- COULD BE ANYTHING, CONTENTION ,INVALID DATA, EMPTY TABLE, # OF FILES EXPECTED NOT EQUAL TO # OF FILES RECEIVED
CC=0020 - COULD BE ANYTHING (CATCHALL)
CC=0030 - DB2 TABLES WRONG DATES
CC=0152 - ERROR ATTEMPTING TO TRANSLATE NEXT TRANSACTION
CC=0696 - FTP LINE DOWN
CC=804 OR 80A - REGION SIZE TOO SMALL - SPECIFY REGION=0M
CC=1000 - BAD DATA, CONTENTION(-911)
CC=1008 - TOTALS OUT OF BALANCE
CC=1016 - NUMBER OF FILES EXPECTED DOES NOT EQUAL NUMBER RECEIVED, BAD DATA, CONTENTION
CC=1999 - DATA EXCEPTION, BAD DATA
CC=2000 - RESOURCE NOT FOUND (07D0), PROGRAMMING ERROR WAITING FOR FILE, RACF(-922), REBIND(-805)
CC=2004 - CYCLE OUT OF SEQUENCE
CC=2016 - TOO MUCH DATA FOR ARRAY SIZE, TABLE UPDATE INCORRECT, NULL DATA
CC=2444 - INVALID RECORD LENGTH
CC=8000 - DATASET ALREADY IN USE, I/O ERROR, FILES NOT SENT RESOURCE NOT AVAILABLE
CC=FFF - FATAL INTER ADDRESS COMMUNICATION ERROR
U046 - NOT ENOUGH OR NO SORT WORK SPACE ALLOCATED.
U048 - USER DOES NOT HAVE ACCESS AUTHORIZATION FOR THE DATASET
U061 - REORDER DATASETS, CHECK BLOCKSIZES. LARGEST BLOCKSIZE FIRST
U063 - CHECK SPELLING OF DD STATEMENTS
U099 - DATASET NOT FOUND
U0000 - DB2 STOPPED UTILID, TABLESPACE
U0003 - Probably trying to process a report that's making it abend. Maybe try purging the report, if you think you can….
U0007/U0240 - VSAM I/O ERROR ON ACKS DATASET(WIDEBAND PROBLEM)
U0100 - USER ERROR
U0102 - PROBLEM WITH CHECKPOINT - MAY NOT HAVE BEEN ANY CHECKPOINTS
U0103 - ENTRY NOT FOUND
U0111 - TAPE TOO SHORT
U0240 - BAD TRANSMISSION
U0378 - I/O ERROR, DIRTY TAPE DRIVE, EQUIP CHECK
U0436 - INVALID REGION ID IN IMS COMMAND
U0437 - RACF, INSUFFICIENT ACCESS AUTHORITY, SECURITY PROBLEM
U0452 - STOPPED TRANSACTION OR PROGRAM
U0456 - PROGRAM DOWN, PROGRAM NOT FOUND
U0457 - TRANSACTION STOPPED, CONTENTION
U0474 - IMS NOT AVAILABLE(COULD BE BECAUSE DB2 CONNECTION IS DOWN)
U0476 - APPLICATION PROGRAM HAS INVALID PCB
U0659 - TAPE POSITIONING ERROR
U0688 - IMS DOWN
U0777 - CONTENTION
U0778 - BAD DATA, DATABASE NOT AVAILABLE(CONTENTION), ETC.
U0746 - BAD DFP CODE
U0779/U0888 - VOLUME FENCED
U0999 - BAD DATA
U1812 - I/O ERROR WRITING THE TAPE MARK DURING CLOSING OF A MACRO INSTRUCTION.
U2000 - I/OR ERROR. CHECK THE STEP WHERE THE ABEND OCCURRED. LOOK FOR AN ONCODE ERROR AT THE BOTTOM OF THE JCL.
U2052 - INCREASE REGION SIZE, NOT ENOUGH CORE.
U3042 - DB2 NOT AVAILABLE
U3312 - DBRC INITIALIZATION FAILED. CHECK AUTHORIZED SUBSYSTEM.
U3999 - CONTENTION, BAD DATA
U4047- IMS PROBLEM(POSSIBLY PROGRAM OR TRAN DOWN)
U4048 - GETMAIN PROBLEM - INSUFFICENT STORAGE(INCREASE REGION SIZE)
U4095 - CONTENTION
UFB0 - B37 (SPACE)
UBB8 - BAD TRAILER RECORD
UB888 - (U3000) FILE ID DOES NOT MATCH CONTROL FILE. FILE OUT OF SEQUENCE
UFA2 - INVALID DATA IN CONTROL TABLE
U3E7 - INVALID DESTINATION, DATASET NOT FOUND, BAD DATA, ETC.
U1C8 -
U2500 -
U3000 - FILE OUT OF SEQUENCE
U3303 - DATABASES DOWN
U3391 - BAD DATA
U3501 - BAD DATA, DCB MISSING
U3400 - BAD DATA
U3502 - BAD CONTROL CARD
U3507 - INSERT TO CERIS ACTIVITY LOG, BAD DATA
U4000 - SOURCE DOES NOT EXIST, PROGRAM TERMINATED, BAD DATA
U4002 - DB2 TABLESPACE IN RECP, IN RO DUPLICATE DATA(-904), UNAVAILABLE RESOURCE
U4012 - MISSING REGION PARAMETER
U4092 - CONTENTION
XE03 - DUPLICATE DATASET NAMES
XE04 - CONTENTION
S013-18 - MISSING MEMBER, MEMBER NOT FOUND IN PDS
S013-20 - OPEN MACRO INSTR FOR SEQUENTIAL DATASET USING DCB, BLKSIZE IS NOT A MULTIPLE OF THE LRECL.
S013-34 - INVALID LRECL(INCOMPATIBLE DCB INFO)
S028 - PAGING I/O ERROR
S029 - LINES EXCEEDED
S031 - SPACE REQUESTED NOT AVAILABLE, DECREASE THE SPACE ALLOCATION
S046 - SORT CAPACITY EXCEEDED
S061 - I/O ERROR IN SORT EXEC, CHECK FOR DATA MESSAGES
S063 - SORTIN DATA PROBLEM
S66D - LIBRARY ACCESS PROBLEM. LOOKS THE SAME AS A S106 ABEND.(LLA)
S100 - I/O INTERBLOCK GAP DETECTED WHEN WRITING RECORD
S106 - CAN'T FIND IBM SUBTOUTINE. RECOMPILE AND RERUN
S106-D - INVALID RECORD TYPE IN LOAD MODULE
S106-F - UNCORRECTABLE I/O ERROR WHEN LOADING MODULE.
S137-14 - I/O ERROR READING HEADER LABELS FOR A DATASET
S137-18 - I/O ERROR WHILE POSITIONING A TAPE FOR THE FIRST DATA RECORD
S137-10 I/O ERROR WHILE POSITIONING A TAPE FOR THE END OF A DATASET
S137-1C - AN INVALID TRAILER RECORD WAS READ DURING THE END-OF-VOLUME
S137 - I/O ERROR READING EOF ON MAGNETIC TAPE
S213-04 - I/O ERROR WRITITN THE DCB FO A DATASET
S213-08 - DATASET NOT FOUND ON VOLUME
S04E - RESOURCE UNAVAILABLE, CONTENTION, BAD INPUT, COULD BE ANYTHING READ SYSTEM MESSAGE CODE AND REASON CODE
S213-04 - I/O ERROR WRITING DCB OF A DATASET
S213-18 - DATASET NOT FOUND ON VOLUME
S214-04 - I/O ERROR READING A USER LABEL ON A TAPE
S214-08 - I/O ERROR
S214-0C - EQC - I/O ERROR ON TAPE DRIVE
S222 - JOB CANCELLED
S237-04 - HARDWARE ERROR - BLOCK OF DATA MISSED OR SKIPPED
S237-08 - DSN ON HEADER LABEL DOESN'T MATCH VOLUME SERIAL
S237-567 - HHARDWARE ERROR. THE BLOCK COUNT DOES NOT MATCH TRAILER LABEL
S306 - INSUFFICIENT ACCESS AUTHORITY
S30E - BAD DATA(CHECK ONCODE),CONTENTION
S311 - I/O ERROR READING HEADER LABELS FOR A DATASET
S322 - TIMED OUT, POSSIBLY NO TIME PARAMETER OR OTHER INFO MISSING
S413-04 - UNIT NOT AVAILABLE FOR MOUNTING VOLUME
S413-08 - AN I/O ERROR OCCURRED POSITIONING A MAGNETIC TAPE VOLUME. TABE DRIVE PROBLEM(IF 'EQC' OR 'SIM' IN MSG). TAPE PROBLEM(IF 'SEQ' IN MSG)
S413-18 - UTPROC=RESTART DID NOT WORK
S413-20 - I/O ERROR READING VOLUME LABEL ON A DASD VOLUME
S413-34 - NO REFERBACK, NO LABEL
S522 - TIMED OUT - TAPE NOT MOUNTED, HSM RECALL
S546 - CANCELLED BY OPERATOR OR SYSTEM
S567 - HARDWARE ERROR - BLOCK OF DATA MISSED OR SKIPPED
S613-08 - TAPE POSITIONING ERROR
S613(SF13) - BAD TAPE OR DRIVE - ERROR READING LABEL ON TAPE. IF YOU SEE MESSAGE IN RMDS OUTPUT: DATA SET NAME DOES NOT MATCH FOR A MASTER VOLUME OR INSTALLATION OPTION ALLOWS UPDATE OF ONLY THE LAST FILE ON MASTER VOLUMES CHECK JCL AT FAILED STEP TO MAKE SURE LABEL IS CORRECT - POSSIBLY NO LABEL S637-OC - CONCATENATION ON UNLIKE ATTRIBUTES
S637-2C - I/O ERROR READING HEADER LABEL ON TAPE
S637-34 - I/O ERROR READING END OF VOLUME LABEL
S706 - A LOAD MODULE MARKED FOR THE LINKAGE EDITOR IS NON-EXECUTABLE
S714 - BAD TAPE OR TAPE DRIVE
S714-0C - BAD TAPE DRIVE
S718 - NOT ENOUGH REGION TO LOAD MODULES
S722 - LINES EXCEEDED, ADD A MAIN LINES CARD - //*MAIN LINES=(100,WARNING)
S737-24 - DSN NOT FOUND
S777 - DATA CHECK. TRANSMIT ON INPUT
S806 - PROGRAM NOT FOUND IN LIBRARY, CONTENTION, NO DATA TRANSMITTED
S813-04 - I/O ERROR READING HEADER LABEL ON TAPE
S822 - REGION REQUESTED/REQUIRED COULD NOT BE OBTAINED
S837 - SPACE PROBLEM WITH OUTPUT DATASET, VOL SER COUNT TOO LOW 'VOL=(,,,10)'
S848 - NOT ENOUGH REGION. INCREASE THE REGION SIZE, 'REGION=4096K'
S878 - NOT ENOUGH REGION. INCREASE THE REGION SIZE, 'REGION=4096K' OR
REGION=4M(SAME AS REGION=4096K)
REGION=0M ALL STORAGE AVAILABE
BELOW THE LINE
S878 - REGION SIZE PROBLEM
S878-10 - GETMAIN PROBLEM - INSUFFICIENT STORAGE
S913 - INSUFFICIENT ACCESS AUTHORITY(RACF)
S922 - SPECIFIED MU TIME EXCEEDED
S2333 - DB2 TABLE TIMESTAMP MISMATCH
SB37-04 - NOT ENOUGH SPACE WAS ALLOCATED
SD37 - OUTPUT DSN USED ALL PRIMARY SPACE
SA13-14 - END OF FILE MARK DATASET NOT ON TAPE
S0C4 - ENTRY NOT FOUND
SE37 - ALL SPACE USED ON CURRENT VOLUME. SPECIFY MORE VOLUMES
JCLI - SYNTAX, DATASET NOT FOUND
JCL - SYNTAX, DATASET NOT FOUND, SPACE, DUPLICATE NAME, CONTENTION COULD BE ANYTHING
07D5 - I/O ERROR
2001 - CONTENTION
2005 - I/O ERROR
2004 - BAD DATA(07D)
2016 - EMPTY GENERATIONS
0406 -
44004 - SQL
013 - OPEN ERROR
028 - PAGING I/O ERROR
052-084 - INVALID CHARACTER ID
076-002 - UNABLE TO OPEN DATASET
072-053 - UNABLE TO OPEN DDNAME
0CX - PROGRAM CHECK EXCEPTIONS:
0C1 - OPERATION,
OC4 - PROTECTION/ADDRESSING,
0C5 - ADDRESSING,
0C6 - SPECIFICATION,
0C7 - DATA
706 - NON-EXECUTABLE PROGRAM
804 - INSUFFICIENT VIRTUAL STORAGE
806 - UNABLE TO LOAD (LINK ETC) PROGRAM
80A - INSUFFICIENT VIRTUAL STORAGE
852 - BAD DATA
878 - INSUFFICIENT VIRTUAL STORAGE
998 - CONTENTION, TABLESPACE IN USE
737 - I/O ERROR
A14 - I/O ERROR
B37 - INSUFFICIENT DASD SPACE ON SEQUENTIAL DATASET
D37 - INSUFFICIENT DASD SPACE - NO SECONDARY SPACE ALLOCATED
E37 - INSUFFICIENT DASD SPACE ON PARTITIONED DATASET
SQLCODE= -104 - ILLEGAL SYMBOL, ILLEGAL TOKEN IN SQL STATEMENT
SQLCODE= -110 - EMPTY TABLE, BAD QUERY
SQLCODE= -180 - THE STRING REPRESENTATION OF A DATETIME VALUE BAD DATA HAS INVALID SYNTAX
SQLCODE= -181 - THE STRING REPRESENTATION OF A DATETIME VALUE IS BAD DATA NOT A VALID DATETIME VALUE
SQLCODE= -204 - UNDEFINED TABLE NAME - TABLE NAME DOESN'T EXIST UNDEFINED ALIAS - ALIAS DOES NOT EXIST
SQLCODE= -305 - THE NULL VALUE CANNOT BE ASSIGNED TO OUTPUT BECAUSE NO INDICATOR VARIABLE IS SPECIFIED
SQLCODE= -501 - CURSOR IS CLOSED DUE TO PREVIOUS CONDITIONS
SQLCODE= -551 - DOES NOT HAVE THE PRIVILEGE TO PERFORM OPERATION DROP ALIAS ON OBJECT
SQLCODE= -556 - CANNOT HAVE THE EXECUTE PRIVILEGE, REVOKED BY DB2DBA BECAUSE THE REVOKEE DOES NOT POSSESS THE PRIVILEGE OR THE REVOKER DID NOT MAKE THE GRANT
SQLCODE= -626 - THE ALTER STATEMENT IS NOT EXECUTABLE BECAUSE PAGE SET IS NOT STOPPED - CALL DBA
SQLCODE= -803 - DATA PROBLEM - MAY BE BAD PART NUMBER COULD BE DUPLICATE VALUES IN EXISTING ROW
SQLCODE= -811 - ERROR ON SQL TABLE
SQLCODE= -818 - LOAD MODULE AND DBR MODULE OUT OF SYNCH NEED TO DO REBIND
SQLCODE= -904 - CONTENTION
SQLCODE= -911 - CONTENTION
SQLCODE= -922 - TIME STAMP PROBLEM AFTER REBIND
SQLCODE= -923 - DB2 ERROR - SOME DB2 COMPONENT NOT AVAILABLE
SQLCODE= -924 - SUBSYSTEM NOT AVAIALABLE, CONTENTION IN DATABASE
ONCODE=9 - DATA PROBLEM
ONCODE=22 - LENGTH OF RECORD VARIABLE GREATER THAN RECORD LENGTH
ONCODE=0084 - UNDEFINED FILE CONDITION RAISE
ONCODE=1040 - SPACE PROBLEM
ONCODE=3920 - STORAGE PROBLEM
ONCODE=8094 - PROTECTION EXCEPTION - CAUSED BY BAD COMPILE - CALL ADM, B37(SPACE PROBLEM)
ONCODE=8097 - BAD DATA, DATA EXCEPTION
ONCODE=9050 - BAD DATA ERROR MESSAGES TO LOOK FOR IN OUTPUT
'INVALID'
'ERROR'
'RESOURCE NOT AVAILABLE'
'PROGRAM NOT FOUND'
'INVALID RECORD LENGTH'
'FAILED'
'UTILITY NOT COMPATIBLE'
'DOES NOT MATCH'
'DUPLICATE'
'DATASET ALREADY USED'
DUPLICATE DATASET NAME - EITHER THE PROGRAM CONTAINS TWO DATASETS WITH THE SAME NAME, OR A DELETE UNCATALOG STEP IS NOT WORKING
'DUPLICATE UTILITY'
'EMPTY DATASET'
EQC - EQUIPMENT CHECK
FBI - FAILED BY INITIATOR - CHECK THE JCL FOR THE CAUSE OF THE ABEND
PROTECTION EXCEPTION - CAUSED BY A BAD COMPILE. CONTACT A PROGRAMMER
OPEN - MESSAGE STATES THAT DATASETS ARE OPEN
SEQ - TAPE DRIVE PROBLEM
UNABLE TO ALLOCATE SORTWORK SPACE - NO SORTWORK SPACE AVAILABLE. WAIT A LITTLE WHILE UNTIL SOME JOBS FINISH PROCESSING AND THEN RESUBMIT THE JOBS. REASON CODE 00E30083 - DEADLOCK - CONTENTION
REASON CODE 00D70024 - RESOURCE UNAVAILABLE
REASON CODE 00E40034 - STORAGE UNAVAILABLE
REASON CODE 1008 - FTP LINE DOWN
REASON CODE OOE40034 - STORAGE PROBLEM - NOT ENOUGH STORAGE
SIM - PROBLEM WITH DRIVE OR TAPE, I/O ERROR
JCL - ENVIRONMENT CHANGED. NOW UNABLE TO ALLOCATE
CAN The job or started task was cancelled by the operator or by a TSO user.
CCUN The completion code is unknown. The job or started task has ended, but no completion code is available.
JCCE An error during JCC(Job Completion Checker) processing prevented the JCC from determining an error code for the operation.
JCL A JCL error occurred after the job was started or a JCL error was recognized after syntax checking in the internal reader.
JCLI A JCL error occurred immediately, before the job or started task began.
MCP The operation was manually set to error in the MCP dialog
OFxx The system that the operation is defined on has gone offline. The WSOFFLINE parameter on the JTOPTS initialization statement specifies that started operations should be marked in error. xx is the status and extended status of the failing operation. Operations that were running (SS) have a step-code error status of OFFL.
OJCV An error occurred during JCL-variable substitution when the job or started task was submitted, or, OPC/ESA detected an error in the recover statement during automatic recovery.
OSEQ A job or started task began to execute before all of its predecessors had completed.
OSUB A failure occurred when OPC/ESA attempted to submit a job or start a started task. In the case of a started task, it could be that the started task is a subsystem that is not started by JES, or the OPC/ESA subsystem EQQSTC ddname is not allocated to a JES-defined procedure library. For a job, send a note to the OPC administrator to request RACF clearance for the job(s) which hung. Once clearance has been granted, do a 'JR'.
OSUF A failure occurred when OPC/ESA attempted to retreive the JCL for a job or started task. Contact the programmer to find out where the JCL can be copied from.
OSUP A time operation is late. It has passed its deadline.
OSxx The system on which the operation was running has failed. xx is the status and extended status of the failing operation. Jobs that were running (status SS) have a step-code error of OSYS.
PCAN A print operation was cancelled by the operator.
Sxxx System abend code. EG:
S222 - Job cancelled by operator.
S522 - Job timed out (tape mount).

Unless otherwise stated, the content of this page is licensed under GNU Free Documentation License.